Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.1.1.(3)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Fire separations between occupancies that are served by public corridors conforming to Sentence 3.3.1.4.(4), where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence 3.3.1.1.(1) and not require fire separations between occupancies on the basis that:
  • the building is sprinklered throughout, and
  • the occupancies are restricted to certain types.
This is to limit the probability that a fire involving the occupancies will spread to other parts of the building, which could lead to harm to persons.