Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.1.7.(3)
+
Application
Application 1: 
Minimum fire-resistance rating required in Sentence 3.3.1.7.(2) of fire separations referred to in Clause 3.3.1.7.(1)(b) [fire separations used to divide a floor area into zones], where the fire-resistance rating required by Subsection 3.2.2. is permitted to be less than 1 h for:
  • the floor assembly above the floor area, or
  • the floor assembly below the floor area, if there is no floor assembly above.
This applies to floor areas that:
  • are above or below the first storey,
  • are not sprinklered throughout,
  • have a barrier-free path of travel, as stated in Sentences 3.8.1.2.(1) and (2), 3.8.1.4.(1), 3.8.2.1.(1) and (2), and 3.8.2.2.(1), and Article 3.8.2.3., and
  • are divided into zones, as described in Clause 3.3.1.7.(1)(b).
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as stated in Sentence 3.8.1.1.(1), which applies to:
  • houses, including semi-detached houses, duplexes, triplexes, town houses, row houses and boarding houses,
  • buildings of Group F, Division 1 major occupancy, and
  • buildings that are not intended to be occupied on a daily or full-time basis, including automatic telephone exchanges, pumphouses and substations.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.5.2.2.(1).
Exceptions: 
except as stated in Article 9.5.2.3., which applies to apartment buildings.
Application 3: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except as stated in: