Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.1.12.(2)
+
Application
Application 1: 
Sliding doors used in an access to exit, in:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To exempt sliding doors in certain types of occupancies from the application of Sentence 3.3.1.12.(1) and Article 3.3.1.11., which would otherwise require the doors to swing on a vertical axis in the direction of travel, on the basis that there is constant supervision, the building is sprinklered and other safety measures addressing the operation of locking devices are provided.
Top of Page