Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.3.1.12.(3) | Application | Intent |
+ |
Application | Application 1: Movable partitions used
to separate a public corridor from an adjacent business and personal services occupancy or a mercantile occupancy, where the partitions are
not located in the only means of egress.
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To exempt movable partitions in certain locations from the
application of Sentences 3.3.1.12.(1), 3.3.1.11.(1) and (2), which
would otherwise require the doors to swing on a vertical axis in the direction
of travel, on the basis that there is an alternative means of egress available
that does not pass through the movable panels. |
Top of Page |