Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.3.1.23.(1) | Application | Intent |
OS3 | + |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Obstructions, in any occupancy,
that would restrict the width of a normal means of egress from
any part of a floor area to less than 750
mm.
Exceptions:
except where an alternative means of egress is
provided adjacent to, and accessible and plainly visible from, the obstructed means of egress.
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions:
except as stated in Sentence 3.8.1.3.(1), which applies to barrier-free design in buildings described
in Sentence 3.8.1.1.(1).
|
Top of Page | |
Intent | Intent 1: To limit the probability that obstructions will reduce the
width of a means of egress, which could lead to delays in the evacuation or
movement of persons to a safe place in an emergency, which could lead to harm
to persons. |
Top of Page |