Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.2.4.(3)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Location of aisles in places of assembly with rows of fixed seats, in buildings described in Sentence 1.3.3.2.(1).
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(2).
Exceptions: 
except as stated in:
  • Sentence 3.1.6.2.(1), which prohibits air-supported structures from being located above the first storey on any building,
  • Sentence 3.1.6.2.(2), which prohibits air-supported structures from being used for classrooms or for Groups B, C, or Group F, Division 1 major occupancies,
  • Sentence 3.1.6.2.(3), which requires air-supported structures to be designed as open floor spaces without interior walls, mezzanines, intermediate floors or similar construction, and
  • Sentence 3.3.2.4.(4), which applies when there are egress doors at the row ends and the egress doors serve a limited number of seats and rows.
Top of Page
Intent
Intent 1: 
To limit the probability of excessive travel distances to reach the nearest aisle, which could lead to delays in the evacuation or movement of persons to a safe place in an emergency situation, which could lead to harm to persons.
Top of Page