Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.2.7.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Latching release mechanism on doors in an access to exit from a room or suite of assembly occupancy containing an occupant load of more than 100.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(2).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To limit the probability of delays in opening an egress door in an emergency situation, which could lead to delays in the evacuation or movement of a large number of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To expand the application of Sentence 3.8.3.3.(7) to certain doors other than those in a barrier-free path.