Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.2.9.(2)
+
Application
Application 1: 
Minimum height of guards installed along the backs and ends of bleacher seats that:
  • are more than 1 200 mm above the ground or floor, and
  • are not adjacent to a wall.
This applies to guards installed in outdoor and indoor places of assembly with bleacher seats.
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(2).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence 3.3.2.9.(1) and require higher guards on the basis that the protection requirements for bleacher seat locations should be more stringent than that for other types of fixed seating since it is more likely that occupants will stand on the seats.