Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.2.14.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Interior flight of stairs with fewer than 3 risers, where the stairs:
  • are not less than 900 mm wide,
  • are illuminated at all times that occupants are on the premises, and
  • have a handrail on each side.
This applies to Group A, Division 2 occupancies used for serving food and beverages, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(2).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To exempt steps in an establishment serving food and beverages from the application of Sentence 3.4.6.2.(1), as referenced by Sentence 3.3.1.14.(1), on the basis that additional measures [minimum width, illumination and handrails] are incorporated to assist persons to use the steps safely, thus minimizing the risk of injuries.
Top of Page