Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.3.4.2.(4) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Fire-resistance rating of
the fire separation required by Sentence 3.3.5.6.(1) [applying
to the separation of storage garages], where:
This applies to floor
areas or parts of floor areas used or intended
for use as residential occupancies, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To exempt separations between a dwelling unit and an attached
garage from the fire-resistance rating requirements of Sentence 3.3.5.6.(1) on
the basis that the dwelling unit and the attached storage garage are sprinklered
and separated from the remainder of the building. This
[the separation and sprinkler protection] is to limit the probability that
a fire involving the garage will spread to the dwelling unit, which could
lead to damage to the building.
|