Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.4.4.(6)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Egress facilities from a dwelling unit, where the dwelling unit has a second and separate means of egress.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To exempt egress facilities serving a dwelling unit from the requirements of Sentences 3.3.1.3.(8) and (9), and 3.3.1.9.(7) which would otherwise:
  • require a doorway to the exterior, a public corridor or an exterior passageway, or
  • prohibit a dead-end corridor that is longer than 6 m.
This is on the basis that there is a second means of egress from the dwelling unit available if the route through a means of egress leading to the exit is impeded, blocked, or untenable.
This is to limit the probability that persons will not have the choice of an alternative egress route in the case where one route is blocked or obstructed in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.