Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.5.3.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Basements used for the storage, manufacture or handling of volatile solids, liquids or gases that generate explosive air-vapour mixtures or for processes that involve explosive dusts, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • rooms and spaces intended for the storage, manufacture or use of hazardous or explosive material, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(4).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To limit the probability that difficult access to basements will delay emergency responders' access to the area of fire origin, which could lead to delays in fire emergency response operations, which could lead to:
  • delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons, and
  • the spread of fire to other parts of the building, which could lead to harm to persons.
Intent 2: 
To limit the probability that difficulty in providing basements with adequate exhaust ventilation will lead to the accumulation of solids, liquids, gases or dusts to ignitable concentrations in low areas of a building, which could lead to a fire or explosion, which could lead to harm to persons.
Top of Page