Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.5.4.(3)
+
Application
Application 1: 
Fire separations that separate exits from the remainder of the building.
This applies to mechanical storage garages of not more than 4 storeys in building height, in which no persons other than parking attendants are permitted above the street floor level, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • rooms and spaces intended for the storage, manufacture or use of hazardous or explosive material, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(4).
Exceptions: 
except as stated in:
Top of Page
Intent
Intent 1: 
To exempt exits in a mechanical storage garage from the requirements of Sentence 3.4.4.1.(1) for a fire separation on the basis that there are few persons permitted to be above the street floor level, and those who are, are familiar with the building.