This information has been archived because it is outdated and no longer relevant.
Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.3.5.6.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of fire separations that separate storage
garages from other occupancies.
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to:
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To limit the probability that fire will spread from a storage
garage to other parts of the building, which could lead to harm to persons
in the other parts of the building. |
Top of Page |