Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.3.5.9.(1)
OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Minimum fire-resistance rating of fire separations that separate each individual tenancy in a multiple tenant self-storage warehouse classified as an industrial occupancy from the remainder of the building.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to:
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1), and
  • rooms and spaces intended for the storage, manufacture or use of hazardous or explosive material, in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.1.2.(4).
Exceptions: 
except:
Top of Page
Intent
Intent 1: 
To limit the probability that fire will spread from an individual tenancy to other parts of the building, which could lead to harm to persons in the other parts of the building.
Intent 2: 
To supersede the requirements for fire separations of suites and public corridors in Articles 3.3.1.1. and 3.3.1.4.