Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.4.2.1.(3) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Single exits permitted in Sentence 3.4.2.1.(2) from floor areas classified
as Group B or Group C occupancies in buildings not
more than 2 storeys in building
height, where the total occupant load served
by the exit is not more than 60, and where:
This applies to floor
areas that are intended for occupancy, including mezzanines as stated in Sentence 3.4.2.2.(1), in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To limit the probability that differences in elevation between
an exterior exit doorway and the adjacent ground level will lead to excessive
travel distances in an emergency situation, which could lead to delays in
the evacuation or movement of persons to a safe place, which could lead to
harm to persons. |