Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.4.2.1.(5) | Application | Intent |
+ |
Application | Application 1: Exits from rooftop enclosures
that are provided with access to exits in conformance
with Sentences 3.3.1.3.(5) and (6). This applies to exit facilities serving floor areas that
are intended for occupancy, including mezzanines as
stated in Sentence 3.3.1.3.(5), in buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To exclude rooftop enclosures from the application of Sentence 3.4.2.1.(1), which would otherwise require direct access to exits at
the roof level, on the basis that:
Intent 2: To direct Code users to Sentences 3.3.1.3.(5) and (6). |