Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.2.4.(2)
+
Application
Application 1: 
Measurement of travel distance from a suite or a room not within a suite to the nearest exit, where:
This applies to exit facilities serving floor areas that are intended for occupancy, including mezzanines as stated in Sentence 3.4.2.2.(1), in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Top of Page
Intent
Intent 1: 
To exempt travel distance measurement involving a suite or room from the application of Sentence 3.4.2.4.(1), which would otherwise require the measurement from the furthest point in the suite or room, and permit measurement from the egress door of the suite or room, if certain conditions are met.
This is on the basis that the portion of the travel route outside the room or suite is protected from a fire in the rooms or suites leading onto the protected egress route and thus would not be rendered untenable within the time required to achieve occupant safety.