Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.3.3.(2)
OS3OP1OS1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Reduction in the minimum required width of exit stairs, landings and passageways resulting from the swing of swinging doors.
This applies to exits serving floor areas that are intended for occupancy, including mezzanines as stated in Sentence 3.4.2.2.(1), in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except as stated in:
  • Sentence 3.1.6.2.(1), which prohibits air-supported structures from being located above the first storey on any building,
  • Sentence 3.1.6.2.(2), which prohibits air-supported structures from being used for classrooms or for Groups B, C, or Group F, Division 1 major occupancies,
  • Sentence 3.1.6.2.(3), which requires air-supported structures to be designed as open floor spaces without interior walls, mezzanines, intermediate floors or similar construction,
  • Sentence 3.3.1.3.(5), which applies to rooftop enclosures,
  • Sentence 3.4.2.2.(2), which applies to mezzanines that:
    • are not required to terminate at a vertical fire separation [see Article 3.2.8.1.],
    • are not intended for an occupant load more than 60,
    • do not exceed the area limits for rooms and suites in Table 3.4.2.2., and
    • have limited travel distances to egress doors or stairs,
  • Sentence 3.4.2.2.(3), which applies to at least half of the required means of egress from a mezzanine if the mezzanine is not required to terminate at a fire separation as permitted by Sentence 3.2.8.2.(1), and
  • Sentences 3.8.1.3.(1) and 3.8.3.3.(1), which apply to barrier-free design in buildings described in Sentence 3.8.1.1.(1).
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentences 3.4.3.2.(8) and 3.4.3.3.(1), and permit a reduction in the width of exits resulting from the swing of swinging doors if the width reduction is limited.
This is to limit the probability that an exit will be substantially reduced in width, which could lead to:
  • insufficient width to permit efficient egress in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons, and
  • emergency responders being delayed in gaining access to floor areas in an emergency situation, which could lead to delays or ineffectiveness in emergency response operations, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.