Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.6.11.(1)
+OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Direction and axis of swing of exit doors.
This applies, in buildings described in Sentence 1.3.3.2.(1) of Division A, to:
Application 2: 
This also applies to:
  • ramps, stairways and passageways used by the public as access to exits, as stated in Appendix Note A-3.4.6., and
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except:
  • for doors serving a single dwelling unit,
  • as stated in Sentence 3.1.6.2.(1), which prohibits air-supported structures from being located above the first storey on any building,
  • as stated in Sentence 3.1.6.2.(2), which prohibits air-supported structures from being used for classrooms or for Groups B, C, or Group F, Division 1 major occupancies,
  • as stated in Sentence 3.1.6.2.(3), which requires air-supported structures to be designed as open floor spaces without interior walls, mezzanines, intermediate floors or similar construction,
  • as stated in Sentence 3.3.1.3.(5), which applies to rooftop enclosures,
  • as stated in Sentence 3.4.2.2.(2), which applies to mezzanines that:
    • are not required to terminate at a vertical fire separation [see Article 3.2.8.1.],
    • are not intended for an occupant load more than 60,
    • do not exceed the area limits for rooms and suites in Table 3.4.2.2., and
    • have limited travel distances to egress doors or stairs,
  • as stated in Sentence 3.4.2.2.(3), which applies to at least half of the required means of egress from a mezzanine if the mezzanine is not required to terminate at a fire separation as permitted by Sentence 3.2.8.2.(1), and
  • Article 3.4.6.13., which applies to sliding doors.
Top of Page
Intent
Intent 1: 
To limit the probability of delays in opening an exit door that does not open in the direction of travel in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To limit the probability that an exit door that does not open in the direction of travel will be difficult to open in an emergency situation if several persons approach it at the same time and the pressure of the group prevents the first person from pulling the door towards them, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 3: 
To limit the probability that a person falling in front of an exit door that does not open in the direction of travel in an emergency situation will obstruct the opening of the door, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 4: 
To limit the probability of delays in the evacuation or movement of persons to a safe place in an emergency situation, which could lead to harm to persons.