Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.4.6.13.(1) | Application | Intent |
+ |
Application | Application 1: Identification, and direction and axis of swing, of
sliding exit doors, where the door leads directly
to outdoors at ground level. This applies, in buildings described in Sentence 1.3.3.2.(1) of Division A,
to:
Application 2: This also applies to:
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To exempt sliding doors from the requirements of Sentence 3.4.6.11.(1), which would otherwise require doors to normally open in
the direction of exit travel and to swing on their vertical axis, on the basis
that the sliding doors are required to meet the requirements of Sentence 3.3.1.12.(1) and
swing on their vertical axis in the direction of exit travel in an emergency
situation. Intent 2: To expand the application of Sentence 3.3.1.12.(1) to
exit doors. |