Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.6.15.(1)
OS3
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Door opening mechanism, and locking, latching and other fastening devices [door release hardware] on principal entrance doors to buildings and on exit doors.
This applies, in buildings described in Sentence 1.3.3.2.(1) of Division A, to:
Application 2: 
This also applies to:
  • ramps, stairways and passageways used by the public as access to exits, as stated in Appendix Note A-3.4.6., and
  • tents and air-supported structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1).
Exceptions: 
except:
  • for devices on doors serving a contained use area or an impeded egress zone designed to be remotely released in conformance with Article 3.3.1.13.,
  • as stated in Sentence 3.1.6.2.(1), which prohibits air-supported structures from being located above the first storey on any building,
  • as stated in Sentence 3.1.6.2.(2), which prohibits air-supported structures from being used for classrooms or for Groups B, C, or Group F, Division 1 major occupancies,
  • as stated in Sentence 3.1.6.2.(3), which requires air-supported structures to be designed as open floor spaces without interior walls, mezzanines, intermediate floors or similar construction,
  • as stated in Sentence 3.3.1.3.(5), which applies to rooftop enclosures,
  • as stated in Sentence 3.4.2.2.(2), which applies to mezzanines that:
    • are not required to terminate at a vertical fire separation [see Article 3.2.8.1.],
    • are not intended for an occupant load more than 60,
    • do not exceed the area limits for rooms and suites in Table 3.4.2.2., and
    • have limited travel distances to egress doors or stairs,
  • as stated in Sentence 3.4.2.2.(3), which applies to at least half of the required means of egress from a mezzanine if the mezzanine is not required to terminate at a fire separation as permitted by Sentence 3.2.8.2.(1),
  • as stated in Sentence 3.4.6.15.(4), which applies to exit doors permitted to have electromagnetic locks,
  • as stated in Article 3.4.6.16., which applies to banks and mercantile floor areas, and
  • as stated in Sentence 3.8.3.3.(3), which applies to barrier-free design in buildings described in Sentence 3.8.1.1.(1).
Top of Page
Intent
Intent 1: 
To limit the probability of delays in opening principal entrance doors and exit doors in an emergency situation, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To expand the application of Sentences 3.3.1.13.(6) to (8).