Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.4.6.18.(1)
OS3OA1OP1OS1
ObjectiveOS3 Safety in Use
Attribution
Application
Application 1: 
Arabic numerals indicating the assigned floor number.
This applies, in buildings described in Sentence 1.3.3.2.(1) of Division A, to:
Application 2: 
This also applies to:
Exceptions: 
except as stated in:
  • Sentence 3.1.6.2.(1), which prohibits air-supported structures from being located above the first storey on any building,
  • Sentence 3.1.6.2.(2), which prohibits air-supported structures from being used for classrooms or for Groups B, C, or Group F, Division 1 major occupancies,
  • Sentence 3.1.6.2.(3), which requires air-supported structures to be designed as open floor spaces without interior walls, mezzanines, intermediate floors or similar construction,
  • Sentence 3.3.1.3.(5), which applies to rooftop enclosures,
  • Sentence 3.4.2.2.(2), which applies to mezzanines that:
    • are not required to terminate at a vertical fire separation [see Article 3.2.8.1.],
    • are not intended for an occupant load more than 60,
    • do not exceed the area limits for rooms and suites in Table 3.4.2.2., and
    • have limited travel distances to egress doors or stairs, and
  • Sentence 3.4.2.2.(3), which applies to at least half of the required means of egress from a mezzanine if the mezzanine is not required to terminate at a fire separation as permitted by Sentence 3.2.8.2.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that persons using exits will not be familiar with assigned floor numbers, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 2: 
To limit the probability that emergency responders using exits in an emergency situation will not be familiar with assigned floor numbers, which could lead to delays or ineffectiveness in emergency response operations, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.
Intent 3: 
To limit the probability that a person with a visual impairment [or disability] will be unable to determine the floor number by reason of being unable to feel raised numbers, which could lead to delays in the evacuation or movement of persons to a safe place, which could lead to harm to persons.