Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.4.7.3.(1) | Application | Intent |
OS3 | + |
Application | Application 1: Access to fire escapes referred to in Sentence 3.4.7.1.(2) from
a dwelling unit through a casement window having
an unobstructed opening not less than 1 100 mm high by 550
mm wide with a sill height of not more than 900 mm above
the inside floor, where:
This applies to fire escapes serving floor areas that are intended for occupancy,
including mezzanines as stated in Sentence 3.4.2.2.(1),
in buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to:
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To exempt casement windows in dwelling units from the requirement
in the first part of Sentence 3.4.7.3.(1) that access to a fire escape
is required to be through a door, on the basis that the occupants should be
familiar with the method of operating the window and gaining access to the
fire escape. |