Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.5.3.2.(1) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of fire separations that separate a vertical
service space containing a dumbwaiter from other portions of each adjacent storey, in buildings described
in Sentence 1.3.3.2.(1) of Division A. Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], as stated in Sentence 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability that fire in a vertical service
space containing a dumbwaiter, or fire in a storey, will spread to another
storey by means of the vertical service space, which could lead to damage
to the building. Intent 2: To limit the probability that fire will spread from a storey
into a vertical service space containing a dumbwaiter, which could lead to
damage to the building. Intent 3: To supersede the fire separation requirements for vertical
service spaces stated in Sentence 3.6.3.1.(1). |