Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.5.3.3.(2) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Fire separation that
separates a room containing elevator machinery from the elevator hoistway
that it serves, where the room and the hoistway are separated from all other
parts of the building by a fire
separation having a fire-resistance rating not
less than that required for the vertical service space containing
the elevator hoistway. This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], as stated in Sentence 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 3.5.3.3.(1),
which would otherwise require a room containing elevator machinery to be separated
from the elevator hoistway by a fire separation, and waive such separation
if certain conditions are met [the room and the hoistway are separated from
all other parts of the building]. This is to limit the
probability that:
|