Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.6.4.5.(1) | Application | Intent |
OS1 | OP1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Access to horizontal service
spaces, where the horizontal service spaces are
more than 1 200 mm high and 600 mm wide.
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
|
Top of Page | |
Intent | Intent 1: To limit the probability that access to horizontal service
spaces for inspection purposes will not be provided, which could lead to fire
hazards within the horizontal service spaces going unnoticed, which could
lead to a fire or the spread of fire to other parts of the building, which
could lead to harm to persons. Intent 2: To limit the probability that access to horizontal service
spaces for inspection purposes will not be provided, which could delay emergency
responders' access to horizontal service spaces in a fire situation involving
such spaces, which could lead to the spread of fire to other parts of the
building, which could lead to harm to persons. |