Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.6.5.4.(2) | Application | Intent |
OS1 |
Objective | OS1 Fire Safety |
Attribution | |
Application | Application 1: Maximum flame-spread rating and
smoke developed classification of combustible coverings
and linings, including associated adhesives and insulation, [of air duct systems],
in buildings described in Sentence 1.3.3.2.(1) of Division A. Application 2: This also applies to:
Exceptions:
except as exempted in Sentence 3.6.5.4.(3), which applies
to the outer covering of ducts, plenums and other
parts of air duct systems used within an assembly of combustible
construction.
|
Top of Page | |
Intent | Intent 1: To limit the probability that coverings and linings will
have inappropriately high flame-spread and smoke-development properties, which
could lead to the development of an inappropriate amount of smoke and the
spread of fire across the exposed surfaces of the material, which could lead
to the spread of fire and smoke to other parts of the building by means of
the air duct systems, which could lead to harm to persons. |
Top of Page |