Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.8.1.2.(4)
+
Application
Application 1: 
Number of doorways required to be designed in accordance with the requirements of Article 3.8.3.3., where the doorways are located at barrier-free [exterior] pedestrian entrances required by Sentences 3.8.1.2.(1) or (2) that include more than one doorway.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as stated in Sentence 3.8.1.1.(1), which applies to:
  • houses, including semi-detached houses, duplexes, triplexes, town houses, row houses and boarding houses,
  • buildings of Group F, Division 1 major occupancy, and
  • buildings that are not intended to be occupied on a daily or full-time basis, including automatic telephone exchanges, pumphouses and substations.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.5.2.1.(1).
Exceptions: 
except as stated in Article 9.5.2.3., which applies to apartment buildings.
Top of Page
Intent
Intent 1: 
To limit the application of Article 3.8.3.3. to only one doorway per entrance, located in a barrier-free path of travel, under certain conditions.