Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.8.3.10.(2) | Application | Intent |
OA2 | OS3 | + |
Attribution |
(a)
|
Application | Application 1: Clear width of approach to urinals described in Sentence 3.8.3.10.(1), in washrooms required by Article 3.8.2.3. to
be barrier-free [washrooms in a storey to
which a barrier-free path of travel is required
in accordance with Article 3.8.2.1.]. This
applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To exempt urinals from the requirement for a greater minimum
width as stated in Sentence 3.8.1.3.(1) and permit a lesser minimum
width, on the basis that urinals need not be wider to allow proper usage by
persons using manual wheelchairs or other manual mobility assistance devices.
|
Top of Page |