Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.5.2.(1)
+
Application
Application 1: 
Minor combustible components used in the construction of buildings or parts of buildings described in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible construction.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be of noncombustible construction, as stated in Sentence 9.10.6.1.(1).
Top of Page
Intent
Intent 1: 
To exempt certain combustible materials from the application of Sentence 3.1.5.1.(1) on the basis that they are deemed to insignificantly contribute to fire growth and spread.
Intent 2: 
To direct Code users to Sentence 3.1.9.1.(1) and Article 3.1.11.7. for fire stop materials referred to in Clause 3.1.5.2.(1)(c).
Intent 3: 
To exempt tubing for pneumatic controls as stated in Clause 3.1.5.2.(1)(d) from the application of Sentence 3.1.5.16.(1), which applies to combustibility of tubing.