Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.5.21.(1) | Application | Intent |
+ |
Application | Application 1: Decorative wood cladding used on the exterior marquee
fascias of storeys having direct access to a street or access route, on buildings described
in Sentence 1.3.3.2.(1) of Division A that are required to be of noncombustible construction, where the cladding is fire-retardant-treated wood that has been conditioned
in conformance with ASTM D 2898, “Accelerated Weathering of Fire-Retardant-Treated
Wood for Fire Testing,” before being tested in accordance with CAN/ULC-S102, “Test
for Surface Burning Characteristics of Building Materials and Assemblies.”
Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9] that are required to be of noncombustible
construction, as stated in Sentence 9.10.6.1.(1).
|
Top of Page | |
Intent | Intent 1: To exempt certain combustible materials from the application
of Sentence 3.1.5.1.(1) if certain conditions are met, on the basis
that the materials are deemed to insignificantly contribute to the growth
and spread of fire. |
Top of Page |