Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.2.(3)
OP1OS1OP1
ObjectiveOS1 Fire Safety
Attribution
Application
Application 1: 
Materials used to achieve the required fire-resistance rating of firewalls, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except:
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that the materials used to construct a firewall will be easily altered or damaged during use, which could lead to an inability of the firewall to control the spread of fire from one building to another, which could lead to harm to persons in the building not originally involved in the fire.
Intent 2: 
To limit the probability that the materials used to construct a firewall will be easily damaged by falling debris during a fire, which could lead to a failure to resist the spread of fire from one building to another, which could lead to harm to persons in the building not originally involved in the fire.