Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.1.10.2.(4) | Application | Intent |
OP1 | OS1 | OP3 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Materials used to achieve the fire-resistance
rating of firewalls, in buildings described
in Sentence 1.3.3.2.(1) of Division A.
Exceptions:
Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], as stated in Sentence 9.10.11.3.(1). |
Top of Page | |
Intent | Intent 1: To limit the probability that the materials used to construct
the assembly providing the fire-resistance rating of a firewall will be easily
altered or damaged during use, which could lead to an inability of the firewall
to control the spread of fire from an adjacent building to the subject building,
which could lead to damage to the subject building. Intent 2: To limit the probability that the materials used to construct
the assembly providing the fire-resistance rating of a firewall will be easily
damaged by falling debris during a fire, which could lead to an inability
of the firewall to control the spread of fire from an adjacent building to
the subject building, which could lead to damage to the subject building.
Intent 3: To exempt certain materials from the application of Sentence 3.1.10.2.(3) if these materials and their application achieve the minimum
level of performance required by Sentence 3.1.10.2.(4) |