Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.1.10.2.(4)
OP1OS1OP3
ObjectiveOP1 Fire Protection of the Building
Attribution
Application
Application 1: 
Materials used to achieve the fire-resistance rating of firewalls, in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except materials for closures and for firewalls having a fire-resistance rating more than 2 h.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], as stated in Sentence 9.10.11.3.(1).
Top of Page
Intent
Intent 1: 
To limit the probability that the materials used to construct the assembly providing the fire-resistance rating of a firewall will be easily altered or damaged during use, which could lead to an inability of the firewall to control the spread of fire from an adjacent building to the subject building, which could lead to damage to the subject building.
Intent 2: 
To limit the probability that the materials used to construct the assembly providing the fire-resistance rating of a firewall will be easily damaged by falling debris during a fire, which could lead to an inability of the firewall to control the spread of fire from an adjacent building to the subject building, which could lead to damage to the subject building.
Intent 3: 
To exempt certain materials from the application of Sentence 3.1.10.2.(3) if these materials and their application achieve the minimum level of performance required by Sentence 3.1.10.2.(4)
Top of Page