Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.1.1.(5)
+
Application
Application 1: 
Mezzanines, with respect to calculating the building height, in buildings described in Sentence 1.3.3.2.(1) of Division A, where one or more levels of mezzanine is partially or wholly superimposed above another mezzanine in the storey.
Exceptions: 
except as exempted in Sentence 3.2.1.1.(6), which applies to platforms intended solely for periodic inspection and elevated maintenance catwalks that are not used for storage and are constructed with noncombustible materials, unless the building is permitted to be of combustible construction.
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentences 3.2.1.1.(3) and (4), which would otherwise exclude mezzanines from the calculation of building height, and require that under certain conditions [where one or more levels of mezzanine is partially or wholly superimposed above another mezzanine in the storey] each level additional to the first level be considered as a storey in calculating the building height.