Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.3.12.(1)
OP3
ObjectiveOP3 Protection of Adjacent Buildings from Fire
Attribution
Application
Application 1: 
Maximum area of unprotected openings in any exposing building face of an unsprinklered building, where the openings are glazed with:
  • glass block conforming to the requirements of Article 3.1.8.14., or
  • wired glass assemblies conforming to D-2.3.14. in Appendix D.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions: 
except as required in Sentence 3.2.3.7.(8), which applies to the sequence of application of Article 3.2.3.12. with respect to Sentences 3.2.3.7.(1) to (6).
Top of Page
Intent
Intent 1: 
To supersede the requirements of Sentence 3.2.3.1.(1) and permit an increase [doubling] in the area of unprotected openings, if certain conditions are met [openings glazed with certain types of assemblies].
This [the conditions] is to limit the probability of the spread of fire from the subject building to an adjacent building, which could lead to damage to the adjacent building.
Intent 2: 
To direct Code users to Article 3.1.8.14. and D-2.3.14. in Appendix D for requirements pertaining to glass block and wired glass assemblies.