Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

3.2.8.2.(6)
+
Application
Application 1: 
Interconnected floor spaces where:
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A.
Application 2: 
This also applies to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where there are:
  • openings through floors that are not protected by shafts or closures, as stated in Sentence 9.10.1.2.(6), or
  • interconnected floor spaces, as stated in Sentence 9.10.9.5.(1).
Top of Page
Intent
Intent 1: 
To exempt certain interconnected floor spaces from the requirements of Sentence 3.2.8.1.(1) and Articles 3.2.8.3. to 3.2.8.9., which would otherwise require a vertical fire separation or certain fire protection measures, if:
  • the location and number of interconnected floors is limited, which will minimize:
    • vertical fire spread, and
    • delays in emergency responder access and evacuation of occupants,
  • the openings through the floor are used only for stairways, escalators or moving walks, or the interconnected floor space is sprinklered, which will minimize vertical fire spread,
  • the interconnected floor space contains only certain major occupancies, which will minimize fire risks, and
  • the building area is limited, which will minimize delays in emergency responder access and evacuation of occupants.