Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.3.1.4.(3) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Fire-resistance rating of fire separations between public
corridors and the remainder of the storey,
where:
This applies to buildings described
in Sentence 1.3.3.2.(1) of Division A.
Application 2: This also applies to tents and air-supported
structures, as stated in Sentences 3.1.6.1.(1) and 9.10.1.2.(1). |
Top of Page | |
Intent | Intent 1: To exempt fire separations in public corridors from the
application of Sentence 3.3.1.4.(2), which would otherwise require the
fire separation to have a fire-resistance rating, on the basis that the storey
is sprinklered throughout and the corridor does not serve certain occupancies.
This is to limit the probability that a fire will not be suppressed
or controlled, which could lead to:
|
Top of Page |