Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.5.3.1.(1) | Application | Intent |
OS1 | OP1 |
Objective | OP1 Fire Protection of the Building |
Attribution | |
Application | Application 1: Minimum fire-resistance rating of fire separations separating vertical
service spaces used as elevator hoistways from other portions of each
adjacent storey, in buildings described
in Sentence 1.3.3.2.(1) of Division A. Application 2: This also applies to buildings to
which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application
of Part 9], as stated in Sentence 9.10.1.2.(1).
Exceptions:
except as stated in Sentence 3.5.3.1.(2), which applies to
passenger elevators located within interconnected floor
spaces, other than those provided for firefighters in accordance with Article 3.2.6.5.
|
Top of Page | |
Intent | Intent 1: To limit the probability that a fire in an elevator hoistway
or storey will spread to another storey by means of the hoistway, which could
lead to damage to the building. Intent 2: To limit the probability that a fire will spread from a
storey into an elevator hoistway, which could lead to damage to the building.
Intent 3: To supersede the fire separation requirements for vertical
service spaces stated in Sentence 3.6.3.1.(1). |