Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.5.3.1.(2) | Application | Intent |
+ |
Application | Application 1: Passenger elevators located within interconnected
floor spaces provided the elevator machinery is located in a room separated
from the remainder of the building by a fire
separation whose fire-resistance rating is
not less than that required for hoistways by Sentence 3.5.3.1.(1), in buildings described in Sentence 1.3.3.2.(1) of Division A.
Exceptions:
except for elevators provided for firefighters in accordance with Article 3.2.6.5.
|
Top of Page | |
Intent | Intent 1: To exempt passenger elevators in interconnected floor spaces
from the requirements of Sentence 3.5.3.1.(1) if certain conditions
are met. |