Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
3.4.3.2.(3) | Application | Intent |
OS3 |
Objective | OS3 Safety in Use |
Attribution | |
Application | Application 1: Minimum aggregate width of means
of egress serving Group A, Division 4 occupancies,
in buildings described in Sentence 1.3.3.2.(1) of Division A. Application 2: This also applies to:
Exceptions:
except as stated in:
|
Top of Page | |
Intent | Intent 1: To supersede the requirements of Sentence 3.4.3.2.(1) and
allow a relaxation in the width of means of egress, on the basis that there
is a lower exposure risk to occupants in an exterior environment.
This is to limit the probability that means of egress will be of
insufficient width to permit efficient egress in an emergency situation, which
could lead to delays in the evacuation or movement of persons to a safe place,
which could lead to harm to persons.
|
Top of Page |