Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.1.3.(3)
OS2+
ObjectiveOS2 Structural Safety
Attribution
[F20-OS2.1] Applies to structural members where temporary overloading during construction may result in impairment of that or any other member.
Application
Application 1: 
Temporary overloading of permanent and temporary structural members, including formwork and falsework, during the construction of buildings.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A] that are required to be designed to the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the loads applied during construction will exceed the specified construction loads, which could exceed the capacities of the structure, including temporary supports, which could lead to structural failure, which could lead to harm to persons.