Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.6.2.(5)
OS2OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Slope factor for calculating the specified snow load on sloped areas of roofs subject to snow accumulation.
Exceptions: 
except as stated in:
  • Sentence 4.1.6.2.(6), which applies to unobstructed slippery roofs, and
  • Sentence 4.1.6.2.(7), which specifies a slope factor of 1.0 when used in conjunction with shape factors for increased snow loads as given in
    • Clause 4.1.6.2.(8)(b), which applies to sloped roofs in roof valleys, an
    • Clause 4.1.6.2.(8)(e), which applies to sloped roofs subject to snow sliding or meltwater draining from adjacent roofs.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the slope factor will not take into account the site conditions affecting the maximum expected accumulation of snow on roofs, which could lead to structural failure, which could lead to harm to persons.