Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
4.1.6.2.(6) | Application | Intent |
OS2 | OP2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Slope factor for calculating the specified snow load
on unobstructed slippery sloped areas of roofs and other building surfaces
subject to snow accumulation. This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and
to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required
to be designed in accordance with the requirements of Part 4.
Exceptions:
except as stated in Sentence 4.1.6.2.(7), which specifies
a slope factor of 1.0 when used in conjunction with shape factors for increased
snow loads as given in:
|
Top of Page | |
Intent | Intent 1: To limit the probability that the slope factor will not
take into account the site conditions affecting the maximum expected accumulation
of snow on unobstructed slippery sloped roofs, which could lead to structural
failure, which could lead to harm to persons. |
Top of Page |