Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.7.4.(1)
OS2OP2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Due consideration to differences in air pressure on opposite sides of interior walls or partitions of buildings.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the design of interior walls and partitions will not take into account the:
  • wind action on and within the building,
  • stack effect due to the difference between the outdoor and indoor temperature, and
  • mechanical air pressurization of the building.
This is to limit the probability that the difference in air pressure on opposite sides of a wall or partition will exceed the capacity of the wall or partition, which could lead to structural failure of interior walls and partitions, which could lead to harm to persons.