Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.1.5.15.(4)
OS2
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Specified vertical load for the design of guards, their connections and their supporting structures.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and to buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] that are required to be designed in accordance with the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the vertical load for the design of a guard and its supporting structure will not take into account the maximum expected weight of persons sitting on the guard, which could lead to structural failure, which could lead to harm to persons.
Intent 2: 
To clarify that the loads applied vertically at the top of every guard need not be combined with the loads applied horizontally at the top of every guard as specified in Sentence 4.1.5.15.(1).
Top of Page