Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

4.2.2.4.(2)
OS2OP2OP4
ObjectiveOS2 Structural Safety
Attribution
Application
Application 1: 
Reassessment of the design where, during construction, climatic or any other conditions have changed the properties of the soil, rock or groundwater.
This applies to buildings described in Sentence 1.3.3.2.(1) of Division A and buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A] that are required to be designed to the requirements of Part 4.
Top of Page
Intent
Intent 1: 
To limit the probability that the changed properties of the soil, rock or groundwater below the building due to climatic or other conditions, will not be taken into account in the design and construction of the excavation and foundation system, which could lead to structural failure, including the collapse of the excavation, which could lead to harm to persons.
Intent 2: 
To facilitate, through qualification of persons skilled in the interpretation of the properties found for the design, the determination of compliance with this requirement.
Top of Page