Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
4.2.5.6.(1) | Application | Intent |
OP4 |
Objective | OP4 Protection of Adjacent Buildings from Structural Damage |
Attribution | |
Application | Application 1: Control of loss of ground due to water or any other
cause, at all phases of excavation and construction.
|
Top of Page | |
Intent | Intent 1: To limit the probability that loss of ground behind excavations
will occur due to water flow or any other cause, such as densification of
loose cohesionless soils, which could lead to excessive displacement of ground,
which could lead to damage to adjacent buildings. |