Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.
4.2.6.3.(1) | Application | Intent |
OS2 | OP2 |
Objective | OS2 Structural Safety |
Attribution | |
Application | Application 1: Incorrect placement or location of shallow
foundation units.
|
Top of Page | |
Intent | Intent 1: To limit the probability that a shallow foundation unit
will not be located in accordance with the assumptions used for the design
of the foundation system, which could lead to insufficient capacity of the
foundation unit, which could lead to structural failure, which could lead
to harm to persons. Intent 2: To direct Code users to the requirement of Article 2.2.4.7. of Division C with respect to the recording of alterations on the design
drawings. |
Top of Page |