Information identified as archived on the Web is for reference, research or recordkeeping purposes. It has not been altered or updated after the date of archiving. Web pages that are archived on the Web are not subject to the Government of Canada Web Standards. As per the Communications Policy of the Government of Canada, you can request alternate formats on the "Contact Us" page.

5.2.1.3.(1)
OH3OH1OS2
ObjectiveOH3 Noise Protection
Attribution
[F56-OH3.1] Applies to sound transmission calculations.
Application
Application 1: 
Calculations related to heat, air and moisture transfer as well as sound transmission in building materials, components, assemblies and their interfaces described in Sentence 5.1.2.1.(1) that are installed in buildings to which Part 5 applies [see Sentence 1.3.3.2.(1) of Division A for application of Part 5].
Application 2: 
This also applies to cladding assemblies installed on buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9] where:
  • the cladding assembly is not addressed in Section 9.27., or
  • the cladding assembly does not comply with the prescriptive requirements of Section 9.27.
Application 3: 
This also applies to the position of low air and vapour permeance materials within the building assembly relative to the position of materials providing thermal resistance in the assemblies of buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the building assembly:
  • incorporates low permeance materials that act as other than cladding or that are installed on the warm side of the assembly, and
  • is more susceptible to condensation [see Sentences 9.25.1.2.(4) and (5) for combinations of interior and exterior environmental conditions that create a higher risk for condensation].
Application 4: 
This also applies to the design of vapour barriers in buildings to which Part 9 applies [see Sentence 1.3.3.3.(1) of Division A for application of Part 9], where the building assembly is more susceptible to condensation [see Sentences 9.25.4.2.(2) and (3) for combinations of interior and exterior environmental conditions that create a higher risk for condensation].
Top of Page
Intent
Intent 1: 
To limit the probability of the incorrect calculation of sound transmission, which could lead to the inadequate performance of components and assemblies of environmental separators under expected environmental loads, which could lead to occupants being exposed to excessive levels of airborne noise, which could lead to negative effects on the psychological well-being of persons.